Process Control
Missing strands and insulation inside the crimp are frequent reasons for defective contacting in modern wire harnesses. Every single crimp therefore has to be monitored to ensure proper functioning. Systems for process control enable gapless crimp force monitoring to be carried out easily and efficiently and meets the highest standards of quality and performance.
MicroForce 70
Technical data
Cross section range: | 0,35 – 6,0 mm² AVG22 – AVG10 |
Operating voltage: | 24 V DC |
Power supply: | Ext. adapter 100-240V AC |
Dimensions (L × W × H): | 146 × 46 × 106 mm |
Weight: | About 5 kg |
MicroForce 80
Technical data
Cross-section range: | 0,35 – 6,0 mm² AVG22 – AVG10 |
Operating voltage: | 24 V DC |
Power supply: | Ext. adapter 100-240V AC |
Dimensions (L × W × H): | 146 × 46 × 106 mm |
Display: | 5.0” color display with touch function |
Q1240 Strip monitoring
The Q1240 visually monitors the stripping quality during production. It measures the stripping length as well as checks the wire for projecting and splayed wires. Defective products are automatically removed.
Technical data
Conductor cross sections: | 0.13 – 6mm2 |
Full or half strip: | Max.18mm |
Resolution: | 1280×1024 (1.3 MB pixels) |
Communication: | USB 3.0 |
Machine types: | Alpha 530, 550 |
Q1250 Strip monitoring
Intelligent optical strip, seal and crimp monitoring for digital inspection of the crimp quality.
Technical data
Conductor cross sections: | 0.13 – 6mm2 |
Full or half strip: | Max.18mm |
Resolution: | 1280×1024 (1.3 MB piksela) |
Control system: | Komax HMI |
Communication: | USB 3.0 |
Machine types: | Alpha 530, 550 |
ACD Automatic Conductor Detector
This system detects the slightest contact between blade and conductor strand during stripping, setup and production. Based on a capacitive measurement principle, the ACD is integrated in the blade holder and can be operated with standard-stripping blades.
Technical data
Wire cross section range: | 0.13 – 6mm2 |
For copper and aluminum stranded wires. | |
Machine types: | Alpha 355 / 355 S / 356 / 530 / 550, Zeta 640/650, Omega 740/750 |
Can not be used with Q1140. |